16 Rohde & Schwarz R&S
®
BTC Broadcast Test Center
Output parameters
Interface
Standard
in line with R&S
®
Digital I/Q Interface
9
,
I/Q data and control signals, data and
interface clock
Level
LVDS
Connector
26-pin MDR
I/Q sample rate
With source user-defined, the sample rate must be entered via the parameter sample
rate, no I/Q data clock being necessary.
Source
user-defined
Sample rate
max. sample rate depending on connected
receiving device
400 Hz to 100 MHz
Resolution (user-defined)
0.001 Hz
Frequency uncertainty (user-
defined)
< (5 × 10
14
+ relative deviation of
reference frequency) × sample rate (nom.)
I/Q data
Resolution
up to 18 bit
Logic format
two’s complement
Physical signal level
Setting range
0 dBFS to 60 dBFS
Resolution
0.01 dBFS
Bandwidth (RF)
sample rate < 200 MHz (interpolation)
0.625 × sample rate
Input parameters
Input level
peak level
Peak level
Setting range
60 dB to +3 dB, referenced to full scale
Resolution
0.01 dB
Crest factor
Setting range
0 dB to +30 dB
Resolution
0.01 dB
Adjust level function
automatically determines peak level and crest factor of input signal
I/Q swap
I and Q signals swapped
on/off
Interface
Standard
in line with R&S
®
Digital I/Q Interface
9
,
I/Q data and control signals, data and
interface clock
Level
LVDS
Connector
26-pin MDR
I/Q sample rate
With source user-defined, the sample rate must be entered via the parameter sample
rate, no I/Q data clock being necessary. With source digital I/Q in, the sample rate
will be estimated based on the applied I/Q data clock.
Source
user-defined, digital I/Q in
Sample rate
max. sample rate depending on connected
transmitting device
400 Hz to 160 MHz
Resolution (user-defined)
0.001 Hz
Frequency uncertainty
(user-defined)
< (5 × 10
14
+ relative deviation of
reference frequency) × sample rate (nom.)
I/Q data
Resolution
18 bit
Logic format
two’s complement
Bandwidth
sample rate = 160 MHz (no interpolation,
user-defined)
160 MHz
sample rate < 160 MHz (interpolation)
0.625 × sample rate
9
R&S
®
Digital I/Q Interface is a Rohde & Schwarz internal company standard for the transmission of digital I/Q data. It is supported by a wide range of
signal generators, signal analyzers and radiocommunications testers.